Inverter Condenser Fan

In air-cooled HVAC systems, variations in ambient conditions or load can lead to significant fluctuations in condensing pressure and power consumption, necessitating substantial adjustments to the condenser fan speed based on system pressure or temperature. This challenge can be effectively addressed by employing an external variable-frequency condenser fan controller. The controller utilizes a PWM module to drive a Hall-less brushless DC motor, enabling stepless speed regulation within the range of 150 to 1,200 rpm according to system pressure or condensing temperature. For pressure-based (0–5 V) speed control, it supports both R22 and R410A refrigerant applications; alternatively, Modbus communication via the RS-485 interface can be used for remote adjustment. The unit features three opto-isolated digital inputs for acquiring system start-up signals, cooling/heating status signals, and fault inputs during pressure- or temperature-based speed control, with an input voltage of AC 220 V. Analog inputs include three temperature channels and one pressure signal channel. A single passive digital output is provided for fault indication. Input voltage: single-phase AC 220 V ±20%; power consumption: <920 W. Mounting dimensions: 194 mm × 162 mm.

Product Details

In air-cooled HVAC systems, variations in ambient conditions or load can lead to significant fluctuations in the condensing pressure and power consumption of the refrigeration system, necessitating substantial adjustments to the speed of the condenser fan based on system pressure or temperature. This challenge can be effectively addressed by employing an external variable-frequency drive controller for the condenser fan.
Based on system pressure or condensing temperature, a PWM module is used to drive a brushless DC motor without Hall feedback, enabling stepless speed regulation within the range of 150 to 1,200 rpm. When speed is controlled via pressure (0–5 V), the system supports both R22 and R410A refrigerant operating conditions; alternatively, communication-based speed control can be implemented via the Modbus protocol over an RS-485 port.
Three-channel digital input, all opto-isolated, used for acquiring the system power-on signal, cooling and heating signals, and fault input signals during pressure- or temperature-based speed control; input voltage: AC 220 V.
AI input: 3-channel analog temperature inputs, 1-channel pressure signal input.
Channel 1 provides passive DO output for fault feedback.
Input voltage: Single-phase AC 220 V ±20%; Power: <920 W.
Installation dimensions: 194 mm × 162 mm.

Keywords: Inverter Condenser Fan

Product Inquiry

If you have any suggestions, please leave a message or send us an email, and we will reply within one business day of receiving your message or email.

%{tishi_zhanwei}%

Address: 3rd Floor, Building 4, No. 1 Kele Road, Xinbei District, Changzhou City, Jiangsu Province
Fax: +86-519-85118697
Email:sales@saturnchina.com
Official website:http://www.saturnchina.com

Our products


Thermostat

Water-based DC Brushless Fan Coil Unit Controller

Water Media DC Card Reader Controller

Air-Cooled Heat Pump Inverter Heating Unit Controller

Inverter Trigeneration Integrated Unit Controller

Air-cooled cabinet controller

Air-cooled/Chilled and Hot Water Modular Unit Controller

Air/Water Dual-Mode Controller

Inverter Dual-System Modular Unit Controller

Inverter Direct Expansion Unit Controller

Fan Drive Board Controller

Inverter RV Air Conditioning Controller

Follow the official public account

Follow the official public account

Copyright © 2026 Santong (Changzhou) Electronic Technology Co., Ltd. All Rights Reserved.