Air-cooled modular unit (6 compressors)
This is an air-cooled modular unit configured with six compressors (options range from 1 to 6 units per system), six four-way valves, three condenser fans, and one shell-and-tube heat exchanger. Specifically, Condenser Fan No. 1 is shared by Compressors No. 1 and No. 2; Condenser Fan No. 2 is shared by Compressors No. 3 and No. 4; and Condenser Fan No. 3 is shared by Compressors No. 5 and No. 6. When current transformers are selected, the operating currents of the compressors and condenser fans can be monitored. Depending on the required cooling capacity, different addresses can be assigned, allowing up to 12 modules to be connected for multi-module operation. During multi-module operation, the auxiliary electric heating and chilled water pump are controlled by the master module. The unit is equipped with an RS485 remote control port supporting the Modbus protocol, facilitating easy integration with other networked devices. The accompanying ST4KC wired controller features touch-sensitive operation keys and a dot-matrix LCD display capable of showing either four lines of eight Chinese characters or four lines of sixteen English characters. It includes 26 optically isolated DI inputs for unit fault protection and interlock control, with a protected input voltage of DC 12 V. The DO outputs comprise 25 active outputs and 1 passive output, totaling 26 relay groups (rated for resistive loads at AC 220 V/5 A). AI inputs include 11 temperature-sensing channels and 9 operational-current-monitoring channels (optional). The external dimensions are as follows: ST4KC—165 mm × 115 mm × 30 mm (maximum overall size); ST4JP—260 mm × 125 mm.
Product Details
| This is an air-cooled modular unit comprising six compressors (with options for 1 to 6 units), six four-way valves, three condenser fans, and one shell-and-tube heat exchanger per unit. Specifically, Condenser Fan No. 1 is shared by Compressors No. 1 and No. 2; Condenser Fan No. 2 is shared by Compressors No. 3 and No. 4; and Condenser Fan No. 3 is shared by Compressors No. 5 and No. 6. If current transformers are selected, the operating currents of the compressors and condenser fans can be monitored. |
| Depending on the required cooling capacity, different addresses can be assigned, allowing up to 12 modules to be connected for multi-module operation. During multi-module operation, the auxiliary electric heating and chilled water pump are controlled by the master module. |
| Equipped with an RS485 remote control port and Modbus protocol, it can be easily integrated with other network devices. |
| The accompanying ST4KC remote control features touch-sensitive operation buttons and a dot-matrix LCD display that can show four lines of 8 Chinese characters or four lines of 16 English characters. |
| DI inputs: 26 channels, all opto-isolated, for unit fault protection and interlock control; protected input voltage: DC 12 V. |
| DO Outputs: 25 channels of powered outputs and 1 channel of unpowered output, totaling 26 relay sets (resistive load, AC 220 V/5 A). |
| AI input: 11-channel temperature monitoring, 9-channel operating current monitoring (optional). |
|
External dimensions: ST4KC: 165 mm × 115 mm × 30 mm (maximum overall dimensions). ST4JP: 260 mm × 125 mm. |
Keywords: Air-cooled modular unit (6 compressors)
Related Products
Product Inquiry
If you have any suggestions, please leave a message or send us an email, and we will reply within one business day of receiving your message or email.
Address: 3rd Floor, Building 4, No. 1 Kele Road, Xinbei District, Changzhou City, Jiangsu Province
Fax: +86-519-85118697
Email:sales@saturnchina.com
Official website:http://www.saturnchina.com
Our products
Follow the official public account
Copyright © 2026 Santong (Changzhou) Electronic Technology Co., Ltd. All Rights Reserved.
CN
EN