Water-Cooled Dual-System Modular All-in-One Controller
Suitable for use in water-cooled direct-expansion units, water-cooled chilled/hot-water units, and water-cooled trigeneration units, among others. Each module can control 1–2 compressors, and by assigning different addresses, 1–8 modules can be configured to operate in parallel. For water-cooled (water-cooled chilled/hot-air) direct-expansion units, each module can control 2 compressors (with the option of 1–2), along with 2 four-way valves; when operating as a single module or in a multi-module configuration, auxiliary electric heating (optional), the cooling water pump, the waste-heat recovery solenoid valve, and the indoor fan (available in single-speed or three-speed versions) are all controlled by the master module. Operating modes include cooling, ventilation, dehumidification, heating (available on both cooling–heating models), and automatic mode; during cooling and heating, the waste-heat recovery function can be enabled. For water-cooled chilled/hot-water units, each module can control 2 compressors (with the option of 1–2) and 2 four-way valves; whether operating as a single module or in a multi-module configuration, the cooling water pump, the waste-heat recovery solenoid valve, and the chilled-water pump are all controlled by the master module. Operating modes include cooling and heating (available on both cooling–heating models), with the option to enable waste-heat recovery during both cooling and heating. For water-cooled integrated chilled/hot-water trigeneration units, each module can control 2 compressors (with the option of 1–2) and 2 four-way valves; whether operating as a single module or in a multi-module configuration, the cooling water pump, the chilled-water pump, the hot-water pump, the hot-water electric heater (optional), and the make-up water solenoid valve are all controlled by the master module. Operating modes include cooling, heating (available on both cooling–heating models), hot water production, cooling plus hot water (with cooling taking priority), and heating plus hot water (with hot water taking priority). The unit is equipped with an RS485 remote-control port and supports the Modbus protocol, enabling easy integration with other networked devices. The MY6DC features a segment-display LCD with wired control, capable of displaying system operating status, and includes neutral-symbol keys for broad compatibility; it also offers self-adaptive motherboard functionality, automatically switching between display content, fault codes, and parameter-setting items. DI inputs: 12 channels, all opto-isolated, used for high-voltage and low-voltage anomaly protection of the unit, with a protected input voltage of DC 12 V. DO outputs: 10 active outputs and 2 passive outputs, totaling 12 relay groups (resistive load, AC 220 V/5 A). AI inputs: 6 analog channels, all temperature-type; specific definitions vary depending on the model. Physical dimensions: MY6DC: 120.5 mm × 80.24 mm × 25 mm (maximum overall dimensions); MY6EP: 151 mm × 109.4 mm.
Category:
Product Details
| Suitable for use in water-cooled direct-expansion units, water-cooled chiller/heater units, and water-cooled trigeneration units, among others. Each module can control 1–2 compressors, and by assigning different addresses, 1–8 modules can be configured to operate in parallel. |
| In water-cooled (water-cooled chilled/hot-air) direct-expansion units, each module can control 2 compressors (with the option of 1 or 2) and 2 four-way valves. When operating in single-module or multi-module configurations, auxiliary electric heating (optional), the cooling water pump, the waste-heat recovery solenoid valve, and the indoor fan (with options for single-speed or three-speed operation) are all controlled by the master module. Operating modes include cooling, ventilation, dehumidification, heating (available for both cooling and heating models), and automatic mode; during cooling and heating, the waste-heat recovery function can be enabled as an option. |
| In water-cooled chiller/heater units, each module can control 2 compressors (with the option of 1 or 2) and 2 four-way valves. When operating in single-module or multi-module configurations, the chilled-water pump, the waste-heat recovery solenoid valve, and the cooling-water pump are all controlled by the master module. Operating modes include cooling and heating (available for heat–cold models), with the option to activate the waste-heat recovery function during both cooling and heating operations. |
| In a water-cooled chiller–hotwater tri-generation unit, each module can control 2 compressors (with the option of 1 or 2) and 2 four-way valves. Whether operating in single-module mode or in a multi-module configuration, the cooling water pump, chilled water pump, hot water pump, electric hot-water heater (optional), and make-up water solenoid valve are all controlled by the master module. The available operating modes include: cooling, heating (available for cooling–heating models), hot water production, cooling plus hot water (with cooling priority), and heating plus hot water (with hot water priority). |
| Equipped with an RS485 remote control port and Modbus protocol, it can be easily integrated into other network devices. |
| The MY6DC segment LCD with wired control can display the system’s operating status and features a neutral-symbol key for versatile application; it is also self-adaptive to the motherboard, automatically switching between display content, fault codes, and parameter-setting items. |
| DI inputs: 12 channels, all opto-isolated, for abnormal protection of the unit’s high-voltage and low-voltage systems; protection input voltage: DC 12 V. |
| DO Outputs: 10 channels of powered outputs and 2 channels of unpowered outputs, totaling 12 relay sets (resistive load, AC 220 V/5 A). |
| AI input: Six analog channels are of the temperature type, with definitions varying by model. |
|
External dimensions: MY6DC: 120.5 mm × 80.24 mm × 25 mm (maximum overall dimensions) MY6EP: 151 mm × 109.4 mm |
Keywords: Water-Cooled Dual-System Modular All-in-One Controller
Related Products
Product Inquiry
If you have any suggestions, please leave a message or send us an email, and we will reply within one business day of receiving your message or email.
Address: 3rd Floor, Building 4, No. 1 Kele Road, Xinbei District, Changzhou City, Jiangsu Province
Fax: +86-519-85118697
Email:sales@saturnchina.com
Official website:http://www.saturnchina.com
Our products
Follow the official public account
Copyright © 2026 Santong (Changzhou) Electronic Technology Co., Ltd. All Rights Reserved.
CN
EN